Technical data:
Nominal voltage:
250 V
Testing voltage:
1500 V
Temperature range:
For cables 4400001-2-3-4-5-6
0°C +80°C
For cables 4400007-8-9-10-11-12-13
-10°C +80°C
Speed:
For cables 4400001-2-3-4-5-6-11-12-13
220 m/min
For cables 4400007-8-9-10
60 m/min
Acceleration:
For cables 4400001-2-3-4-5-6-11-12-13
10 m/s2
For cables 4400007-8-9-10
2 m/s2
Burning characteristics:
For cables 4400002-6-7-8-9-10
CEI 20-35,
VDE 0472-804 test A,
NFC 32070 cat. C1 test 1,
IEC 332.1
Oil resistance:
For cables 4400001-2-3-6-11-12-13
complying with VDE 0472 part 803 A/B
For cables 4400004-5-7-8-9-10
complying with VDE 0472 part 803 B
Homologation UL/CSA:
For cables 4400001-5-11-12-13
UL-AWM 80°C - 300V
CSA-AWM 75°C - 300V FT1
For cables 4400002-6
UL-AWM 80°C - 30V
CSA-AWM 75°C 30V FT1
Construction:
Conductor:
High flexible
Insulation:
For cables 4400001 Polyolefin
For cables 4400002-6-11-12-13 PP
For cables 4400003-4-5 TPE-E
For cables 4400007-8-9-10 PVC
Core ident.:
coloured
Jacket material:
For cables 4400001 PUR orange RAL 2003
For cables 4400002-6 PUR green RAL 6018
For cables 4400003-4-5-11-12-13 PUR black
For cables 4400007-8-9-10 PVC black
Totally shielded:
Tinned copper braid > 85%
except 4400007-8
Shielded multipair:
for 4400006 (3 Cp - 0,14 mm2 spiral in Cu Tinned copper spiral, coverage >90% on the single groups)
for 4400003 (Tinned copper spiral, single on the 4x0,14 mm2 Overall : Tinned copper coverage >85%)
for 4400004 (Tinned copper spiral, single on the pair coverage >85%)
for 4400007-8-9-10-11-12-13 (Tinned copper braid, single on the pair coverage >85%)
Capacity:
for 4400006-11-12-13 cond./cond. =100 pF/m; cond./scherm. =168 pF/m
for 4400003-4 cond./cond. =140 pF/m; cond./scherm. =235 pF/m
for 4400007-8-9-10-11 cond./cond. =150 pF/m; cond./scherm. =270 pF/m